Description
LPCB certified to the latest versions of EN54 Parts 2 and 4
Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry to access level 2
2 zone circuits
4 conventional sounder circuits
Integral 1.5A EN54-4/A2 compliant switch mode PSU
Two on-board relays (Fire and Fault)
Two open-collector outputs (Remote and Reset)
‘Class change’ and alert inputs
Installer-friendly design accommodates easy first fix and straightforward maintenance
Attractive flush or surface mountable plastic lid and enclosure - no bezel required
Low 25mA quiescent current
Multiple indicators
End of line units included (one per zone)
Ancillary system expansion connections provided for up to eight two-wire repeaters (one F/CHSC/RDC network driver card required per system).
Space for two x 12V 3.2Ah VRLA batteries (not included; code: MLCSLA12)
Dimensions: H235 x W380 x D96mm
Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry to access level 2
2 zone circuits
4 conventional sounder circuits
Integral 1.5A EN54-4/A2 compliant switch mode PSU
Two on-board relays (Fire and Fault)
Two open-collector outputs (Remote and Reset)
‘Class change’ and alert inputs
Installer-friendly design accommodates easy first fix and straightforward maintenance
Attractive flush or surface mountable plastic lid and enclosure - no bezel required
Low 25mA quiescent current
Multiple indicators
End of line units included (one per zone)
Ancillary system expansion connections provided for up to eight two-wire repeaters (one F/CHSC/RDC network driver card required per system).
Space for two x 12V 3.2Ah VRLA batteries (not included; code: MLCSLA12)
Dimensions: H235 x W380 x D96mm
- LPCB certified to the latest versions of EN54 Parts 2 and 4
- Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry to access level 2
- 2 zone circuits
- Four conventional sounder circuits
- Integral 1.5A EN54-4/A2 compliant switch mode PSU
- Two on-board relays (Fire and Fault)
- Two open-collector outputs (Remote and Reset)
- ‘Class change’ and alert inputs
- Installer-friendly design accommodates easy first fix and straightforward maintenance
- Attractive flush or surface mountable plastic lid and enclosure - no bezel required
- Low 25mA quiescent current
- Multiple indicators
- End of line units included (one per zone)
- Ancillary system expansion connections provided for up to eight two-wire repeaters (one F/CHSC/RDC network driver card required per system)
- Space for two x 12V 3.2Ah VRLA batteries (not included; code: MLCSLA12)
- Dimensions: H235 x W380 x D96mm